  • Product Description
  • Key Performance Benefits

    • N+1 Redundancy in a Single Frame — One spare 18kVA module covers the frame, so the loss of any single module does not interrupt the protected load.
    • Online Module Replacement — Power modules are exchanged while the UPS remains in double conversion, avoiding a transfer to bypass during service work.
    • 18kVA Redundancy Granularity — Redundancy is added in 18kVA steps, so the spare capacity is sized to the frame rather than purchased as an entire second system.
    • 96.5% Double Conversion Efficiency — Redundant operation does not require accepting avoidable conversion loss, keeping heat and energy cost controlled.
    • Unitary Power Factor (PF=1.0) — Each module delivers its full rating in kW, so fewer modules cover the same real load with redundancy in place.
    • Load Sharing Across Modules — Modules share the load automatically, so a remaining unit carries the full IT demand without manual intervention after a fault.
    • Intelligent Battery Monitoring — Testing and deep discharge protection support the same availability objective on the DC side as on the AC side.

    Technical Specifications

    Technical IndicatorSpecification Detail (APM90)
    Power Rating18kVA to 90kVA (Scalable in 18kVA modules)
    TopologyModular Online Double Conversion
    Redundancy OptionsN, N+1 or N+X within a single frame
    Module Size18kVA/18kW High-Density Power Modules
    Conversion EfficiencyUp to 96.5% (Double Conversion) / Up to 99% (ECO Mode)
    Frame CapacityUp to 90kVA/kW per frame
    Service AccessFront-access hot-swap modules with LCD/LED management interface

    APM90: Redundancy That Does Not Require a Second UPS

    Conventional redundancy planning forces a choice between buying a full second UPS cabinet or accepting a single point of failure in the power path.

    A parallel system doubles the footprint, cabling and switchgear, while a non-redundant unit leaves the entire load exposed to one rectifier or inverter fault.

    The reason the decision is difficult is that protection is purchased at full-cabinet cost even when only a fraction of capacity needs to be duplicated.

    The Vertiv Liebert APM90 resolves that trade-off by providing redundancy at 18kVA module granularity inside one frame, so a single spare module covers the installation.

    Because modules share load automatically, the remaining units continue to carry the IT demand if one fails, without operator action and without a transfer to static bypass.

    Service work follows the same logic: a module is extracted and replaced while the UPS stays in double conversion, keeping the load on conditioned power throughout the maintenance window.

    At 96.5% double-conversion efficiency, running with a spare module does not require tolerating avoidable losses, and the unitary power factor means each module contributes its full rating in kW.

    Battery testing and deep discharge protection apply the same availability discipline to the DC side, where many outages originate.

    Specifying the Liebert APM90 with N+1 modular redundancy gives IT rooms the availability profile of a parallel system without the cost and space of a second cabinet. Module-level spares replace cabinet-level duplication, and online replacement avoids the load transfers that turn routine maintenance into a risk event. Efficiency above 96.5% keeps the redundant configuration economically defensible, while unitary power factor reduces the module count needed to cover the same load. For facility teams accountable for continuous operation in space-constrained rooms, the APM90 delivers redundancy as an incremental design choice rather than a structural one.

    Technical FAQ

    Q: How is load handled if two modules fail simultaneously?

    A: Remaining modules continue to supply the load up to their combined rating; whether the load is fully supported depends on configuration and actual demand at the time of the fault.

    Q: Does module replacement require an external bypass cabinet?

    A: Modules are hot-swappable within the frame; the need for external bypass depends on site procedures and the maintenance policy applied to the installation.

Certification


Songli

Application


Songli

FAQ


Are we a trader or a manufacturer?

To be exact, we are an officially authorized agent and can get in touch with the manufacturers directly to enjoy a high proportion of cost discounts.

How to pack?

Can be packaged according to customer's needs

How long is your delivery time?

If the goods are in stock, generally 5-10 days. If there is no stock and an order needs to be placed, it needs to be determined according to the delivery dates of different brands.

Customer Visits


Songli
Songli
Songli

Warehouse


Our warehouse is located in the core logistics area with convenient transportation, covering an area of 1000 square meters, designed specifically for efficient, safe, and convenient storage and distribution.

There are brand new UPS (uninterruptible power supply), precision air conditioning, and various types of telecommunications power products from brands such as Vertiv, Huawei, Eltek, and Delta in the warehouse, as well as base station and data center equipment. These products are stored properly under intelligent management and environmental control, ensuring that every customer can receive the highest quality and most reliable products.

Whether it is large equipment or small electrical products, there are strict quality inspections and records at every step from warehousing to outbound, ensuring the safety and cycle management of goods.

In addition to efficient warehousing services, we also provide comprehensive logistics distribution, covering multiple transportation modes such as sea, land, and air, ensuring worry free storage and instant delivery of goods.

Songli
Songli
Songli
Songli

Vertiv Liebert APM90 UPS 18kVA to 90kVA

Key Performance BenefitsN+1 Redundancy in a Single Frame — One spare 18kVA module covers the frame, so the loss of any single module does not interrupt the protected load.Online Module Replacement — Power modules are exchanged while the UPS remains in double conversion, avoiding a transfer to bypass during service work.18kVA Redundancy Granularity — Redundancy is added in 18kVA steps, so the spare capacity is sized to the frame rather than purchased as an entire second system.96.5% Double Conversion Efficiency — Redundant operation does not require accepting avoidable conversion loss, keeping heat and energy cost controlled.Unitary Power Factor (PF=1.0) — Each module delivers its full rating in kW, so fewer modules cover the same real load with redundancy in place.Load Sharing Across Modules — Modules share the load automatically, so a remaining unit carries the full IT demand without manual intervention after a fault.Intelligent Battery Monitoring — Testing and deep discharge protection support the same availability objective on the DC side as on the AC side.Technical SpecificationsTechnical IndicatorSpecification Detail (APM90)Power Rating18kVA to 90kVA (Scalable in 18kVA modules)TopologyModular Online Double ConversionRedundancy OptionsN, N+1 or N+X within a single frameModule Size18kVA/18kW High-Density Power ModulesConversion EfficiencyUp to 96.5% (Double Conversion) / Up to 99% (ECO Mode)Frame CapacityUp to 90kVA/kW per frameService AccessFront-access hot-swap modules with LCD/LED management interfaceAPM90: Redundancy That Does Not Require a Second UPSConventional redundancy planning forces a choice between buying a full second UPS cabinet or accepting a single point of failure in the power path.A parallel system doubles the footprint, cabling and switchgear, while a non-redundant unit leaves the entire load exposed to one rectifier or inverter fault.The reason the decision is difficult is that protection is purchased at full-cabinet cost even when only a fraction of capacity needs to be duplicated.The Vertiv Liebert APM90 resolves that trade-off by providing redundancy at 18kVA module granularity inside one frame, so a single spare module covers the installation.Because modules share load automatically, the remaining units continue to carry the IT demand if one fails, without operator action and without a transfer to static bypass.Service work follows the same logic: a module is extracted and replaced while the UPS stays in double conversion, keeping the load on conditioned power throughout the maintenance window.At 96.5% double-conversion efficiency, running with a spare module does not require tolerating avoidable losses, and the unitary power factor means each module contributes its full rating in kW.Battery testing and deep discharge protection apply the same availability discipline to the DC side, where many outages originate.Specifying the Liebert APM90 with N+1 modular redundancy gives IT rooms the availability profile of a parallel system without the cost and space of a second cabinet. Module-level spares replace cabinet-level duplication, and online replacement avoids the load transfers that turn routine maintenance into a risk event. Efficiency above 96.5% keeps the redundant configuration economically defensible, while unitary power factor reduces the module count needed to cover the same load. For facility teams accountable for continuous operation in space-constrained rooms, the APM90 delivers redundancy as an incremental design choice rather than a structural one.Technical FAQQ: How is load handled if two modules fail simultaneously?A: Remaining modules continue to supply the load up to their combined rating; whether the load is fully supported depends on configuration and actual demand at the time of the fault.Q: Does module replacement require an external bypass cabinet?A: Modules are hot-swappable within the frame; the need for external bypass depends on site procedures and the maintenance policy applied to the installation.

Still hesitating? Get the samples first,Contact Us!

  • Product Description
  • Key Performance Benefits

    • N+1 Redundancy in a Single Frame — One spare 18kVA module covers the frame, so the loss of any single module does not interrupt the protected load.
    • Online Module Replacement — Power modules are exchanged while the UPS remains in double conversion, avoiding a transfer to bypass during service work.
    • 18kVA Redundancy Granularity — Redundancy is added in 18kVA steps, so the spare capacity is sized to the frame rather than purchased as an entire second system.
    • 96.5% Double Conversion Efficiency — Redundant operation does not require accepting avoidable conversion loss, keeping heat and energy cost controlled.
    • Unitary Power Factor (PF=1.0) — Each module delivers its full rating in kW, so fewer modules cover the same real load with redundancy in place.
    • Load Sharing Across Modules — Modules share the load automatically, so a remaining unit carries the full IT demand without manual intervention after a fault.
    • Intelligent Battery Monitoring — Testing and deep discharge protection support the same availability objective on the DC side as on the AC side.

    Technical Specifications

    Technical IndicatorSpecification Detail (APM90)
    Power Rating18kVA to 90kVA (Scalable in 18kVA modules)
    TopologyModular Online Double Conversion
    Redundancy OptionsN, N+1 or N+X within a single frame
    Module Size18kVA/18kW High-Density Power Modules
    Conversion EfficiencyUp to 96.5% (Double Conversion) / Up to 99% (ECO Mode)
    Frame CapacityUp to 90kVA/kW per frame
    Service AccessFront-access hot-swap modules with LCD/LED management interface

    APM90: Redundancy That Does Not Require a Second UPS

    Conventional redundancy planning forces a choice between buying a full second UPS cabinet or accepting a single point of failure in the power path.

    A parallel system doubles the footprint, cabling and switchgear, while a non-redundant unit leaves the entire load exposed to one rectifier or inverter fault.

    The reason the decision is difficult is that protection is purchased at full-cabinet cost even when only a fraction of capacity needs to be duplicated.

    The Vertiv Liebert APM90 resolves that trade-off by providing redundancy at 18kVA module granularity inside one frame, so a single spare module covers the installation.

    Because modules share load automatically, the remaining units continue to carry the IT demand if one fails, without operator action and without a transfer to static bypass.

    Service work follows the same logic: a module is extracted and replaced while the UPS stays in double conversion, keeping the load on conditioned power throughout the maintenance window.

    At 96.5% double-conversion efficiency, running with a spare module does not require tolerating avoidable losses, and the unitary power factor means each module contributes its full rating in kW.

    Battery testing and deep discharge protection apply the same availability discipline to the DC side, where many outages originate.

    Specifying the Liebert APM90 with N+1 modular redundancy gives IT rooms the availability profile of a parallel system without the cost and space of a second cabinet. Module-level spares replace cabinet-level duplication, and online replacement avoids the load transfers that turn routine maintenance into a risk event. Efficiency above 96.5% keeps the redundant configuration economically defensible, while unitary power factor reduces the module count needed to cover the same load. For facility teams accountable for continuous operation in space-constrained rooms, the APM90 delivers redundancy as an incremental design choice rather than a structural one.

    Technical FAQ

    Q: How is load handled if two modules fail simultaneously?

    A: Remaining modules continue to supply the load up to their combined rating; whether the load is fully supported depends on configuration and actual demand at the time of the fault.

    Q: Does module replacement require an external bypass cabinet?

    A: Modules are hot-swappable within the frame; the need for external bypass depends on site procedures and the maintenance policy applied to the installation.

Certification


Songli

Application


Songli

FAQ


Are we a trader or a manufacturer?

To be exact, we are an officially authorized agent and can get in touch with the manufacturers directly to enjoy a high proportion of cost discounts.

How to pack?

Can be packaged according to customer's needs

How long is your delivery time?

If the goods are in stock, generally 5-10 days. If there is no stock and an order needs to be placed, it needs to be determined according to the delivery dates of different brands.

Customer Visits


Songli
Songli
Songli

Warehouse


Our warehouse is located in the core logistics area with convenient transportation, covering an area of 1000 square meters, designed specifically for efficient, safe, and convenient storage and distribution.

There are brand new UPS (uninterruptible power supply), precision air conditioning, and various types of telecommunications power products from brands such as Vertiv, Huawei, Eltek, and Delta in the warehouse, as well as base station and data center equipment. These products are stored properly under intelligent management and environmental control, ensuring that every customer can receive the highest quality and most reliable products.

Whether it is large equipment or small electrical products, there are strict quality inspections and records at every step from warehousing to outbound, ensuring the safety and cycle management of goods.

In addition to efficient warehousing services, we also provide comprehensive logistics distribution, covering multiple transportation modes such as sea, land, and air, ensuring worry free storage and instant delivery of goods.

Songli
Songli
Songli
Songli

Get Quote

NOTE: Please leave your email, our professional person will contact you asap!